Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 307
Filtrar
1.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 32(2): 541-545, 2024 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-38660864

RESUMO

OBJECTIVE: To explore the feasibility of establishing combat readiness blood bank with low titer group O whole blood and group A plasma. METHODS: The Galileo automatic blood analyzer was used to detect the titers of IgM anti-A and anti-B antibodies in the samples of group O blood donors and IgM anti-B titer in the samples of group A blood donors. Group O blood donors with antibody titers below 128 were selected and included in the mobile blood bank for combat readiness, group A plasma with anti-B titer lower than 128 and group O whole blood with antibody titers below 128 were included in the combat readiness entity blood bank. RESULTS: A total of 1 452 group O blood donors were selected, and the anti-A/B antibody titers were detected. Both antibody titers were distributed below 512, and both peak values of sample distribution were at titer 4. The proportion of samples with titers>128 for both antibodies was relatively low. There was a significant positive correlation between the titers of the two antibodies (r =0.383), and the proportion of samples with IgM anti-A titer higher than IgM anti-B titer was relatively high. 1 335(91.94%) group O blood donors with IgM anti-A and anti-B antibody titers <128 could be included in the mobile blood bank. The anti-B titer of group A blood was detected in 512 cases and the results showed that as the antibody titer increased, the proportion of blood donors gradually decreased. 99.8% of group A blood donors had anti-B antibody titer less than 128, and only one case did not meet the inclusion criteria. CONCLUSION: The proportion of group O blood donors whose whole blood meet the low antibody titer standard is high, and almost all plasma of group A blood donors meet the low titer standard, which improves the blood supply rate in emergencies.


Assuntos
Sistema ABO de Grupos Sanguíneos , Bancos de Sangue , Doadores de Sangue , Imunoglobulina M , Humanos , Sistema ABO de Grupos Sanguíneos/imunologia , Imunoglobulina M/sangue , Estudos de Viabilidade , Tipagem e Reações Cruzadas Sanguíneas , Plasma
2.
Perfusion ; : 2676591241240725, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38519444

RESUMO

INTRODUCTION: A radical paradigm shift in the treatment of premature infants failing conventional treatment is to recreate fetal physiology using an extracorporeal Artificial Placenta (AP). The aim of this study is to evaluate the effects of changing fetal hemoglobin percent (HbF%) on physiology and circuit function during AP support in an ovine model. METHODS: Extremely premature lambs (n = 5) were delivered by cesarean section at 117-121 d estimated gestational age (EGA) (term = 145d), weighing 2.5 ± 0.35 kg. Lambs were cannulated using 10-14Fr cannulae for drainage via the right jugular vein and reinfusion via the umbilical vein. Lambs were intubated and lungs were filled with perfluorodecalin to a meniscus with a pressure of 5-8 cm H2O. The first option for transfusion was fetal whole blood from twins followed by maternal red blood cells. Arterial blood gases were used to titrate AP support to maintain fetal blood gas values. RESULTS: The mean survival time on circuit was 119.6 ± 39.5 h. Hemodynamic parameters and lactate were stable throughout. As more adult blood transfusions were given to maintain hemoglobin at 10 mg/dL, the HbF% declined, reaching 40% by post operative day 7. The HbF% was inversely proportional to flow rates as higher flows were required to maintain adequate oxygen saturation and perfusion. CONCLUSIONS: Transfusion of adult blood led to decreased fetal hemoglobin concentration during AP support. The HbF% was inversely proportional to flow rates. Future directions include strategies to decrease the priming volume and establishing a fetal blood bank to have blood rich in HbF.

3.
BMJ Open ; 14(3): e083688, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38448082

RESUMO

INTRODUCTION: Sickle cell disease (SCD) poses a significant global health burden, particularly affecting individuals in developing countries with constrained healthcare resources. While research on self-management in the context of SCD is emerging, it has predominantly focused on primary studies, and there is a notable dearth of evidence synthesis on SCD self-management in developing countries. This scoping review aims to identify and map self-management needs of individuals living with SCD, the strategies they employed to meet those needs, and the support systems available to them. METHODS AND ANALYSIS: The review will be conducted following the Arksey and O'Malley's (2005) 29 framework to comprehensively examine the landscape of SCD self-management research. Searches will be performed in PubMed, Scopus, Embase and Dimensions AI, with additional searches in other databases and grey literature. Indexed literature published in English from inception to January 2024 will be included. Reference list from included studies will also be searched manually. Two teams will be constituted to independently screen titles, abstracts and full text against the eligible criteria. Data will be extracted from included studies onto a customised data extraction form. ETHICS AND DISSEMINATION: Ethical approval is not required for this review due to the fact that it synthesises information from available publications. The findings will be disseminated through publication in a peer-reviewed journal. Also, the findings will possibly be presented at relevant international and national conferences. This protocol has already been registered with the Open Science Framework. The study characteristics such as design and setting will be descriptively analysed and presented as graphs, tables and figures. Thematic analysis will also be conducted based on the study objectives and presented as a narrative summary.


Assuntos
Anemia Falciforme , Autogestão , Humanos , Países em Desenvolvimento , Anemia Falciforme/terapia , Bases de Dados Factuais , Literatura Cinzenta , Literatura de Revisão como Assunto
4.
J Spec Oper Med ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38446068

RESUMO

BACKGROUND: Fast and reliable blood collection is critical to emergency walking blood banks (WBB) because mortality significantly declines when blood is quickly administered to a warfighter with hemorrhagic shock. Phlebotomy for WBB is accomplished via either the "straight stick" (SS) or "ruggedized lock" (RL) method. SS comprises a 16-gauge phlebotomy needle connected to a blood collection bag via tubing. The RL device collects blood through the same apparatus, but has a capped, intravenous (IV) catheter between the needle and the donor's arm. This is the first study to compare these two methods in battlefield-relevant metrics. METHODS: Military first responders and licensed medical providers (N=86) were trained in SS and RL as part of fresh whole blood training exercises. Outcomes included venipuncture success rates, time to IV access, blood collection times, total time, and user preferences, using a within-subjects crossover design. Data were analyzed using ANOVA and nonparametric statistics at p<0.05. RESULTS: SS outperformed RL in first venipuncture success rates (76% vs. 64%, p=0.07), IV access times (448 [standard error of the mean; SE 23] vs. 558 [SE 31] s, p<0.01), and blood collection bag fill times (573 [SE 48] vs. 703 [SE 44] s, p<0.05), resulting in an approximate 3.5-minute faster time overall. Survey data were mixed, with users perceiving SS as simpler and faster, but RL as more reliable and secure. CONCLUSION: SS is optimal when timely collection is imperative, while RL may be preferable when device stability or replacing the collection bag is a consideration.

5.
J Clin Med ; 13(4)2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38398261

RESUMO

Background: Access to blood products is crucial for patient safety during the perioperative course. However, reduced donations and seasonally occurring blood shortages pose a significant challenge to the healthcare system, with surgeries being postponed. The German Blood Transfusion act requires that RBC packages become assigned to an individual patient, resulting in a significant reduction in the available blood products, further aggravating shortages. We aimed to develop a scoring system predicting transfusion probability in patients undergoing spine surgery to reduce assignment and, thus, increase the availability of blood products. Methods: The medical records of 252 patients who underwent spine surgery were evaluated and 18 potential predictors for RBC transfusion were tested to construct a logistic-regression-based predictive scoring system for blood transfusion in patients undergoing spine surgery. Results: The variables found to be the most important included the type of surgery, vertebral body replacement, number of stages, and pre-operative Hb concentration, indicating that surgical specification and the extent of the surgical procedure were more influential than the pre-existing patient condition and medication. Conclusions: Our model showed a good discrimination ability with an average AUC [min, max] of 0.87 [0.6, 0.97] and internal validation with a similar AUC of 0.84 [0.66, 0.97]. In summary, we developed a scoring system to forecast patients' perioperative transfusion needs when undergoing spine surgery using pre-operative predictors, potentially reducing the need for RBC allocation and, thus, resulting in an increased availability of this valuable resource.

6.
Transfusion ; 64(4): 656-664, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38385641

RESUMO

BACKGROUND: Special Forces (SF) teams operate in remote environments with limited medical support. As a result, they may need to rely on buddy transfusions to treat bleeding teammates. Considering that 450 mL has no direct impact on their combat performances, it might be tempting to take more blood from a compatible donor to save a hemorrhaging teammate. This study investigates the effect of a 900 mL blood donation on SF operator performance and recovery time following this donation. STUDY DESIGN AND METHODS: Participants underwent a multifactorial assessment including measures of physiological parameters, vigilance, and physical performance. Results from the day of blood donation were compared with baseline values obtained 1 week earlier (i.e., immediate effect), as well as repeated testing at 7, 14, and approximately 30 days after blood donation (i.e., recovery period). RESULTS: Hemoglobin levels and heart rate were affected by giving blood. The participants also experienced a significant decrease in physical performance of more than 50% immediately after blood donation. Recovery was slow over the following weeks, remaining significantly different from baseline until full recovery around day 30. However, participants were still able to respond to a simple stimulus and adjust their response, if necessary, even immediately after donating blood. DISCUSSION: A 900 mL blood donation greatly affects the physical fitness of SF operators. A donation may be worthwhile if it is the only life-saving procedure available and does not endanger the donor's life. The donor would then become a patient and unable to complete the mission.


Assuntos
Doação de Sangue , Doadores de Sangue , Humanos , Transfusão de Sangue
7.
BMJ Open ; 14(2): e078953, 2024 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-38316586

RESUMO

INTRODUCTION: Uncontrolled bleeding is a major cause of death for patients with major trauma. Current transfusion practices vary, and there is uncertainty about the optimal strategy. Whole blood (WB) transfusion, which contains all components in one bag, is considered potentially advantageous, particularly for resuscitating patients with major bleeding in the prehospital setting. It could potentially improve survival, reduce donor risk and simplify the processes of delivering blood transfusions outside hospitals. However, the evidence supporting the effectiveness and safety of WB compared with the standard separate blood component therapy is limited. A multicentre randomised controlled trial will be conducted, alongside an implementation study, to assess the efficacy, cost-effectiveness and implementation of prehospital WB transfusion in the prehospital environment. The implementation study will focus on evaluating the acceptability and integration of the intervention into clinical settings and on addressing broader contextual factors that may influence its success or failure. METHODS AND ANALYSIS: A type 1 effectiveness-implementation hybrid design will be employed. The implementation study will use qualitative methods, encompassing comprehensive interviews and focus groups with operational staff, patients and blood donor representatives. Staff will be purposefully selected to ensure a wide range of perspectives based on their professional background and involvement in the WB pathway. The study design includes: (1) initial assessment of current practice and processes in the WB pathway; (2) qualitative interviews with up to 40 operational staff and (3) five focus groups with staff and donor representatives. Data analysis will be guided by the theoretical lenses of the Normalisation Process Theory and the Theoretical Framework of Acceptability. ETHICS AND DISSEMINATION: The study was prospectively registered and approved by the South Central-Oxford C Research Ethics Committee and the Health Research Authority and Health and Care Research Wales. The results will be published in peer-reviewed journals and provided to all relevant stakeholders. TRIAL REGISTRATION NUMBER: ISRCTN23657907; EudraCT: 2021-006876-18; IRAS Number: 300414; REC: 22/SC/0072.


Assuntos
Transfusão de Sangue , Hemorragia , Humanos , Hemorragia/terapia , País de Gales , Grupos Focais , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
8.
J Spec Oper Med ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38408045

RESUMO

BACKGROUND: Tactical Combat Casualty Care (TCCC) guidelines recognize low-titer group O whole blood (LTOWB) as the resuscitative fluid of choice for combat wounded. Utilization of prescreened LTOWB in a walking blood bank (WBB) format has been well described by the Ranger O low-titer blood (ROLO) and the United States Marine Corps Valkyrie programs, but it has not been applied to the maritime setting. METHODS: We describe three WBB experiences of an expeditionary resuscitative surgical system (ERSS) team, attached to three nontraditional maritime medical receiving platforms, over 6 months. RESULTS: Significant variations were identified in the number of screened eligible donors, the number of LTOWB donors, and the timely arrival at WBB activation sites between the platforms. Overall, 95% and 84% of the screened eligible group O blood donors on the Arleigh Burke Class Destroyer (DDG) and Nimitz Class Aircraft Carrier (CVN), respectively, were determined to be LTOWB. However, only 37% of the eligible screened group O blood donors aboard the Harper's Ferry Class Dock Landing Ship (LSD) were found to be LTOWB. Of the eligible donors, 66% did not complete screening, with 52% citing a correctable reason for nonparticipation. CONCLUSION: LTOWB attained through WBBs may be the only practical resuscitative fluid on maritime platforms without inherent blood product storage capabilities to perform remote damage control resuscitation. Future efforts should focus on optimizing WBBs through capability development, education, and training efforts.

9.
Vox Sang ; 119(4): 363-367, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38245847

RESUMO

BACKGROUND AND OBJECTIVES: Solid organ transplant surgeries including liver transplants constitute a substantial risk of bleeding complications and given frequent national blood shortages, supporting D-negative transplant recipients with D-negative red blood cell products perioperatively can be difficult for the transfusion services. This study was designed to compare the incidence of alloimmunization after D-mismatched red cell transfusions between patients with and without a history of solid organ transplant at a single tertiary care hospital. The patients undergoing solid organ transplants are on strong immunosuppressive regimens perioperatively to help reduce the risk of rejection. We hypothesized that the use of these immunosuppressive agents makes these patients very less likely to mount an immune response and form anti-D antibodies when exposed to the D-positive red blood cell products perioperatively. STUDY DESIGN AND METHODS: At our center, D-negative patients who received ≥1 unit of D-positive red blood cell products were identified using historical transfusion records. Antibody testing results were examined to determine the incidence of the formation of anti-D and any other red cell alloantibodies after transfusion and these results were compared between patients with and without a history of solid organ transplant. RESULTS: We were able to identify a total of 22 patients over 10 years with D-negative phenotype who had undergone a solid organ transplant and had received D-positive red blood cell products during the transplant surgeries. We also identified a second group of 54 patients with D-negative phenotype who had received D-positive red blood cell products for other indications including medical and surgical. A comparison of the data showed no new anti-D formation among patients with a history of D mismatched transfusion during solid organ transplant surgeries. CONCLUSION: Among our limited study population, we observed a very low likelihood of D alloimmunization among solid organ transplant recipients. A larger, prospective study could help further evaluate the need for prophylactic D matching for red cell transfusions during solid organ transplant surgeries.


Assuntos
Transfusão de Sangue , Transplante de Órgãos , Imunoglobulina rho(D) , Humanos , Estudos Prospectivos , Incidência , Eritrócitos , Isoanticorpos
10.
Transfus Med ; 34(1): 46-53, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38165014

RESUMO

Knowledge regarding the profile of eligible blood donors presenting positive results in laboratory screening is essential for reducing transfusion-transmitted human immunodeficiency virus (HIV), hepatitis B virus (HBV) and hepatitis C virus (HCV). Our study aimed to evaluate the prevalence, incidence, predictor variables and residual risk (RR) of HIV/HBV/HCV in blood bags donated in Minas Gerais, Brazil. This study analysed data retrieved from the records of a large blood bank relating to donations collected at multiple centres within the period 2012-2018, during which 1 991 120 blood bags were screened using immunoassays and nucleic acid tests (NATs). Multilevel modelling was used to investigate the association between sex, civil status and age group with HIV/HBV/HCV. RR was estimated from the incidence values (restricted to negative and positive tests within the study period) and window periods for infections. The prevalence in first time donors, incidence and RR of HCV (223.73 cases per 100 000; 54.84 per 100 000 persons-year and 1.6527 per 100 000, respectively) were higher than those of HIV (172.65 cases per 100 000; 28.25 per 100 000 persons-year and 0.8514 per 100 000) and HBV (168.17 cases per 100 000; 18.54 per 100 000 persons-year and 0.5588 per 100 000). The odds of acquiring infection were greater in male, single and older donors. Sixteen donors were identified as seronegative and NATs+ during the 7-year span of the study. Our study has clarified some spatiotemporal trends regarding HIV/HBV/HCV infections in donated blood in Brazil. The results will contribute to the formulation of directives addressed to high-risk donors.


Assuntos
Infecções por HIV , Hepatite B , Hepatite C , Masculino , Humanos , Feminino , Incidência , Hepatite B/epidemiologia , Brasil/epidemiologia , Doadores de Sangue , Prevalência , Fatores de Risco , Hepatite C/epidemiologia , Vírus da Hepatite B , Infecções por HIV/epidemiologia , Hepacivirus
11.
Transfus Med ; 34(1): 30-38, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38193379

RESUMO

OBJECTIVES: Our objective was to compare the measurement of residual white blood cell (rWBC) and residual red blood cell (rRBC) counts in blood products using the XN Blood Bank mode and the laboratory standard operating procedures for manual counts. In addition, to compare the whole blood complete blood count (CBC) values of blood donors and the quality of blood products using the Sysmex XN analyser versus the XS-1000i analyser. MATERIALS AND METHODS: For blood donors, 190 samples from blood or apheresis donors were analysed on both the Sysmex XS-1000i and XN-1000 analysers and the mean values of six CBC parameters were compared: the white blood cell count (WBC), the red blood cell count (RBC), haemoglobin (HGB), haematocrit (HCT), the mean corpuscular volume (MCV), the platelet count (PLT). For blood products, 164 samples were collected: 13 Plasma products - whole blood, 9 Plasma products - apheresis, 36 RBC concentrates - whole blood, 30 PLT concentrates - buffy coats, 36 PLT concentrates - buffy coats - pooled and 55 PLT concentrates - apheresis. RESULTS: All CBC parameters of the blood donors tested showed similar performance, with excellent correlation coefficients (r) ranging from 0.821 to 0.995. The majority of the blood products did not have a quantifiable number of residual cells, meaning the number of rWBC and rRBC, if present, was below the limit of quantitation (LoQ) of the different methods. rWBC were detected by Blood Bank mode in Plasma products - whole blood with a mean rWBC of 0.012 × 109 /L and in PLT concentrates - buffy coats with a mean rWBC of 0.19 × 109 /L. The correlation coefficient in both analysers for all three parameters (HGB, HCT, RBC) in RBC concentrates - whole blood was excellent, ranging from 0.95 to 0.99. For platelet count, r ranged from 0.98 to 0.99. CONCLUSION: The XN-Series analyser, equipped with a Blood Bank mode, demonstrated reliable performance when used for blood donor evaluation, rWBC enumeration and measurement of end blood products.


Assuntos
Bancos de Sangue , Doadores de Sangue , Humanos , Contagem de Células Sanguíneas/métodos , Contagem de Plaquetas , Eritrócitos
12.
Cell Tissue Bank ; 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38168846

RESUMO

Umbilical cord blood is a rich source of hematopoietic stem cells that has been used for transplantation for over 30 years, especially when there is no compatible hematopoietic stem cell donor available. Its use has decreased more recently, since the development of methods to improve haploidentical transplants has allowed the use of mobilized peripheral blood as a source of hematopoietic stem cells. Public cord blood banks collect, process and store cord blood samples from voluntary donations. In addition, many public banks are involved in research to enhance hematopoietic stem cell therapies and develop new treatments for haematological and genetic diseases. The COVID-19 pandemic, which emerged in 2019, has had a profound and wide-ranging impact on human health and treatment. The area of hematopoietic stem cell transplantation was deeply affected by reductions in bone marrow, peripheral blood and cord blood donations; logistical challenges; exposure of healthcare workers and other challenges. The present study reviews the impact of the COVID-19 pandemic on cord blood banking and transportation around the world with a special focus on Brazil.

13.
BMJ Open ; 14(1): e080952, 2024 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-38267243

RESUMO

INTRODUCTION: Postoperative anaemia is prevalent in adult spinal deformity (ASD) surgery in association with unfavourable outcomes. Ferric derisomaltose, a novel iron supplement, offers a promising solution in rapidly treating postoperative anaemia. However, the clinical evidence of its effect on patients receiving spinal surgery remains inadequate. This randomised controlled trial aims to evaluate the safety and efficacy of ferric derisomaltose on postoperative anaemia in ASD patients. METHODS AND ANALYSIS: This single-centre, phase 4, randomised controlled trial will be conducted at Department of Orthopaedics at Peking Union Medical College Hospital and aims to recruit adult patients who received ASD surgery with postoperative anaemia. Eligible participants will be randomly assigned to receive ferric derisomaltose infusion or oral ferrous succinate. The primary outcome is the change in haemoglobin concentrations from postoperative days 1-14. Secondary outcomes include changes in iron parameters, reticulocyte parameters, postoperative complications, allogeneic red blood cell infusion rates, length of hospital stay, functional assessment and quality-of-life evaluation. ETHICS AND DISSEMINATION: This study has been approved by the Research Ethics Committee of Peking Union Medical College Hospital and registered at ClinicalTrials.gov. Informed consent will be obtained from all participants prior to enrolment and the study will be conducted in accordance with the principles of the Declaration of Helsinki. The results of this study are expected to be disseminated through peer-reviewed journals and academic conferences. TRIAL REGISTRATION NUMBER: NCT05714007.


Assuntos
Anemia , Adulto , Humanos , Anemia/tratamento farmacológico , Anemia/etiologia , Ferro , Dissacarídeos , Eritrócitos , Ensaios Clínicos Controlados Aleatórios como Assunto , Ensaios Clínicos Fase IV como Assunto , Compostos Férricos
14.
Ann Lab Med ; 44(3): 262-270, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38098300

RESUMO

Background: Maintaining optimal blood inventory levels in hospitals is important to prevent blood shortage and wastage. We aimed to provide an efficient blood inventory management strategy for hospital blood banks nation-wide by comparing the current use of 5-day issuable stock (IS) with Lim's IS as a novel target IS. Methods: The average and CV of daily usage (DU) were calculated from information entered into Korea's Blood Management System by 194 participating hospitals in 2019 and 2020. Using these data, Lim's IS was calculated by determining the simulated annual average blood shortage day nearest to 1 for each blood group in each hospital. The 5-day IS (5IS) was estimated by multiplying the average DU in 2018 by five to count the shortage days in 2019. Results: The average DU (0.3-231.3 units) and corresponding CV (0.33-7.14) in the participating hospitals were inversely proportional (r=-0.699 to -0.695). The hypothetical averages of 5IS and Lim's IS were 27.0±41.2 and 24.7±20.8, respectively (P=0.006). The shortage days for 5IS and Lim's IS were 8.9±22.7 and 1.0±1.9, respectively (P<0.001). Conclusions: While 5IS was unacceptable for universal application, Lim's IS remained near one shortage day and is considered more efficient than 5IS. Hospitals should implement indicators that consider DU and its variations. This is the first study to introduce Lim's IS as an indicator of optimal blood inventory, and the data are expected to provide guidance for effective blood inventory management nationwide, particularly during blood shortages.


Assuntos
Bancos de Sangue , Hospitais , Humanos , República da Coreia
15.
Transfus Apher Sci ; : 103854, 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38061923

RESUMO

BACKGROUND: Poor disinfection is the main cause of blood contamination, so its elimination is key to limiting the entry of bacteria into the collection system. With the advancement of antiseptic technology, antiseptics with sterile, disposable applicators are now available. AIM: To evaluate in situ two antiseptics (with and without applicators) for blood banks and to demonstrate in vitro antiseptic activity on bacterial biofilms of importance in transfusion medicine. METHODS: Antiseptic A (2% sterile solution of chlorhexidine gluconate/70% isopropyl alcohol provided with applicator) and bulk antiseptic B (10% povidone-iodine) were evaluated. The deferred blood donor arms were subjected to disinfection with antiseptics A and B and the contralateral arms were cultured to determine the baseline bacterial load (control). Antiseptic activity was assessed by ANOVA and logaritmic reduction values (LRV) and percentage reduction values (PRV) were calculated. Finally, the in vitro activity of antiseptic A was analyzed by confocal laser scanning microscopy (CLSM) on biofilm models. RESULTS: Prior to disinfection tests, commensal and clinically important bacteria were identified; antiseptic A showed post-disinfection bacterial growth rates of zero compared to controls (p < 0.0001). The frequency of bacterial growth with antiseptic B was 74%. A significant difference was identified between both antiseptics, where antiseptic A showed higher activity (p < 0.5468). LRV and PRV were 0.6-2.5/100% and 0.3-1.7/66.7-99.7% for antiseptics A and B, respectively. Through CLSM, disinfectant A (without applicator) showed lower in vitro antiseptic activity on the tested biofilms at the exposure times recommended by the manufacturer. CONCLUSIONS: Sterile solution of chlorhexidine gluconate/isopropyl alcohol with applicator showed advantages disinfection in deferred blood donors over povidone-iodine.

16.
BMJ Open ; 13(12): e075070, 2023 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-38101848

RESUMO

INTRODUCTION: Transfusions in surgery can be life-saving interventions, but inappropriate transfusions may lack clinical benefit and cause harm. Transfusion decision-making in surgery is complex and frequently informed by haemoglobin (Hgb) measurement in the operating room. Point-of-care testing for haemoglobin (POCT-Hgb) is increasingly relied on given its simplicity and rapid provision of results. POCT-Hgb devices lack adequate validation in the operative setting, particularly for Hgb values within the transfusion zone (60-100 g/L). This study aims to examine the accuracy of intraoperative POCT-Hgb instruments in non-cardiac surgery, and the association between POCT-Hgb measurements and transfusion decision-making. METHODS AND ANALYSIS: PREMISE is an observational prospective method comparison study. Enrolment will occur when adult patients undergoing major non-cardiac surgery require POCT-Hgb, as determined by the treating team. Three concurrent POCT-Hgb results, considered as index tests, will be compared with a laboratory analysis of Hgb (lab-Hgb), considered the gold standard. Participants may have multiple POCT-Hgb measurements during surgery. The primary outcome is the difference in individual Hgb measurements between POCT-Hgb and lab-Hgb, primarily among measurements that are within the transfusion zone. Secondary outcomes include POCT-Hgb accuracy within the entire cohort, postoperative morbidity, mortality and transfusion rates. The sample size is 1750 POCT-Hgb measurements to obtain a minimum of 652 Hgb measurements <100 g/L, based on an estimated incidence of 38%. The sample size was calculated to fit a logistic regression model to predict instances when POCT-Hgb are inaccurate, using 4 g/L as an acceptable margin of error. ETHICS AND DISSEMINATION: Institutional ethics approval has been obtained by the Ottawa Health Science Network-Research Ethics Board prior to initiating the study. Findings from this study will be published in peer-reviewed journals and presented at relevant scientific conferences. Social media will be leveraged to further disseminate the study results and engage with clinicians.


Assuntos
Transfusão de Sangue , Hemoglobinas , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Humanos , Transfusão de Sangue/métodos , Canadá , Hemoglobinas/análise , Hospitais , Estudos Observacionais como Assunto
17.
Int J Med Stud ; 11(1): 22-28, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38031547

RESUMO

Background: Hemorrhagic shock is the second leading cause of death for injured people and disproportionately affects low resource economies. The potential role of spatial allocation of blood banks and the unmet transfusion needs of patients are yet to be characterized. We aimed to estimate the effect of the number of blood banks in mortality due to traumatic hemorrhagic shock (THS) in Colombia. Methods: We performed a population-based cross-sectional study using secondary data from the Colombian Government: including annual reports from the Blood Bank Network, mortality, and population estimates for 2015-2016. International Classification of Disease 10th code T79.4 identified THS as the primary cause of death. A city-clustered multivariate negative binomial regression, weighted by violent deaths rate, was used to obtain incidence rate ratios (IRR) of death due to THS with 95% confidence intervals (95%CI). Results: Of the 59,030 violent deaths in Colombia in 2015-2016, 36.76% were due to THS. Only 3.13% of Colombian municipalities had a blood bank. THS incidence decreased as the number of blood banks in a city increased, and the lowest incidence was observed at ten banks (IRR:0.18, 95%CI:0.15-0.22). Receiving medical care in a city with blood banks had a more substantial impact on THS (IRR:0.85; 95%CI:0.76-0.96). Conclusion: The number of blood banks per city was associated with lower incidence of THS deaths. These findings may highlight the inequitable distribution of blood systems and their association with preventable deaths. Further studies with more focused clinical and geographical data might clarify the geographic determinants of blood products' availability.

18.
BMC Health Serv Res ; 23(1): 1169, 2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37891622

RESUMO

BACKGROUND AND PURPOSE: Hemovigilance is a set of monitoring methods that covers the blood transfusion chain, from collecting blood and blood products to monitoring the blood recipients. To this end, any error in this process can have serious and irreparable consequences for patients. The present study aimed to investigate the quality of hemovigilance process in Iran, using the first two steps of Six Sigma model. METHODS: This was a quantitative cross-sectional study that was conducted over 6 months (from August 20, 2021, to February 20, 2022) at Afzalipour Hospital in Iran, using the first two steps of Six Sigma model. The study population comprised of all inpatients who needed blood or blood product transfusion in various departments of Afzalipour Hospital, among whom 477 patients were selected via stratified sampling in three shifts (morning, evening, and night). The datasheet was used to record errors in the three shifts. This research was conducted, using the DMAIC cycle's "define" and "measure" steps. RESULTS: In the define step, the hemovigilance process at Afzalipour Hospital was divided into two categories of normal process and emergency process. Each of these processes consists of several sub-processes, including "phlebotomy," "requesting blood and blood products from the department," "preparation of application by the blood bank," " sending a request from the blood bank to the blood transfusion center," "transfusing blood and blood products," and "returning the blood and blood products to the blood bank and waste disposal." In the measure step, the quality of hemovigilance process was evaluated based on sub-processes and labels at morning, evening and night shifts. The sub-process of sending a request from the blood bank to the blood transfusion center had the highest error rate with a sigma level of 1.5. Also, the evening and night shifts had a sigma level of 1.875, and the clinical and registration labels had a sigma level of 1.875. The overall sigma level of hemovigilance process was calculated to be 2. CONCLUSION: The results of this study showed that the quality of hemovigilance process at Afzalipour Hospital was poor. By employing the first two steps of Six Sigma method, we identified the existing errors in the hemovigilance process of Afzalipour hospital in order to assist hospital managers to take the necessary measures to improve this process.


Assuntos
Segurança do Sangue , Gestão da Qualidade Total , Humanos , Estudos Transversais , Transfusão de Sangue , Bancos de Sangue
19.
BMJ Mil Health ; 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37709507

RESUMO

Whole blood transfusion is being increasingly used for trauma resuscitation, particularly in military settings. Low-titre group O whole blood simplifies the logistical challenges and maximises the benefits of blood transfusion when compared with component therapy in austere battlefield conditions. Screening protocols and blood testing requirements for prescreened donors in walking blood banks (WBBs), which are used for emergency transfusions, are established by both the USA and most partner nations, though they are not necessarily uniform across these combined forces. Interoperability and standardisation of blood bank resources and protocols across allied forces in multinational military operations, including uniformity in screening processes, collection methods and storage is essential to the provision of safe and effective blood product transfusions in this austere setting. Predeployment screening, multinational training exercises and universal WBB sets with instructions in multiple languages can help enhance the interoperability of combined multinational operations and create a more efficient WBB system. Standardisation of blood collection, nomenclature, equipment and screening practices will allow for the most optimal utilisation of whole blood resources across a multinational battlefield.

20.
Blood Sci ; 5(3): 209-217, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37546709

RESUMO

The unforeseen and uncertain life-threatening situation of the COVID-19 pandemic dramatically affected all areas of the human daily work schedule. This study was designed to assess the impact of the COVID-19 pandemic on blood transfusion services and discuss the adopted confrontation measures for uninterrupted blood supply during the pandemic situation. The data on blood donation, blood component preparation, and issue from January 2019 to December 2022 were collected from the inventory registers of the RBTC, Delhi, India. Compared to the non-pandemic year 2019, during the year 2020, all variables decreased gradually. The observed maximum decrease in variables such as blood collection (-79.16%) in the month of October, blood issue (-71.61%) in the month of August, random donor platelets (RDP) preparation (-98.09%) in the month of October, RDP issue (-86.08%) in the month of September, fresh frozen plasma (FFP) preparation (-100%) in the month of October, and FFP issue (-96.08%) in the month of July with an annual decrease of -45.52%, -42.87%, -33.00%, -59.79%, -40.98%, and -54.48%, respectively, as compared to year 2019. Compared to year 2020, in year 2021, the annual increase in blood collection, blood issue, FFP preparation, FFP issue, RDP preparation, and RDP issue was +50.20%, +21.68%, +65.31%, +78.52%, +116.23%, and +213.30%, respectively. Our study results show that the COVID-19 pandemic has significantly affected blood transfusion services at our blood bank. The adopted coping strategies to maintain the safe and uninterrupted blood transfusion chain at our blood bank gave us lessons for future preparedness if faced with a similar situation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...